In need of urgent assistance? Call +86-13427815151 

新闻与咨询

New industry Technology regarding to Bussmann fuse, ABB breakers, Amphenol connectors, HPS transformers, etc. 

Bussmann FWH and FWP Fuse Series: Ferrule Fuses for 500-700 Vdc EV and Industrial Applications

Time:2026-05-29   Author:As Beam   Browse:


The Ferrule Form Factor

Both FWH and FWP fuses use a cylindrical body with ferrule (cap) terminals -- the same form factor as standard IEC 60269-4 semiconductor fuses. This cylindrical ferrule design offers practical advantages: compatibility with standard DIN rail clips and busbar-mounted fuse holders; uniform heat dissipation without hot spots; proven automotive vibration and thermal cycling performance meeting ISO 16750 requirements; and field replaceability by trained technicians without specialized tools.

 Bussmann FWH and FWP Fuse Series: Ferrule Fuses for 500-700 Vdc EV and Industrial Applications

FWH Series -- 500 Vdc, 50 kA

Part Number

Rating

Voltage

IR

FWH-35C

35A

500 Vdc

50 kA

FWH-100C

100A

500 Vdc

50 kA

FWH-200C

200A

500 Vdc

50 kA

FWH-350C

350A

500 Vdc

50 kA

FWH-500C

500A

500 Vdc

50 kA

FWH-800C

800A

500 Vdc

50 kA

 


 

FWP Series -- 700 Vdc, 50 kA

Part Number

Rating

Voltage

IR

FWP-35C

35A

700 Vdc

50 kA

FWP-125C

125A

700 Vdc

50 kA

FWP-250C

250A

700 Vdc

50 kA

FWP-400C

400A

700 Vdc

50 kA

FWP-600C

600A

700 Vdc

50 kA

 

FWJ Series -- 800 Vdc, 50 kA (Imperial Ferrule)

Part Number

Rating

Voltage

IR

FWJ-35A

35A

800 Vdc

50 kA

FWJ-125A

125A

800 Vdc

50 kA

FWJ-250A

250A

800 Vdc

50 kA

FWJ-400A

400A

800 Vdc

50 kA

FWJ-600A

600A

800 Vdc

50 kA

 

Voltage Selection: FWH vs FWP vs FWJ

Select the lowest voltage family that provides adequate margin above your maximum system voltage. For a 400V nominal system (approximately 460V peak at full charge), FWH at 500 Vdc provides 8.7% voltage margin -- acceptable for most applications. For a 600V nominal system (approximately 690V peak), FWP at 700 Vdc provides only 1.4% margin -- marginal for some applications. FWJ at 800 Vdc provides 15.9% margin for the same 600V system, often preferred for robust protection. The FWJ uses imperial (inch-based) ferrule dimensions, which may affect holder compatibility compared to the metric FWH-C and FWP-C series. Verify holder compatibility before specifying.

 

FWH/FWP/FWJ Applications in EV and ESS

 In EV: FWH-C is used for OBC AC input protection (500V rating provides adequate margin above 400Vac input), DC-DC converter input/output protection, and low-voltage battery pack protection in 200-400V architectures. In ESS: FWH-C for battery rack combiner protection (500V tier) and PCS DC side protection for 500V-class BESS. FWP for 600-700V battery bus protection where FWH's 500V rating is insufficient. FWJ for 800V battery bus protection in a ferrule form factor where the 170M square-body size is too large.


New industry Technology regarding to Bussmann fuse, ABB breakers, Amphenol connectors, HPS transformers, etc. 


TAG:  Bussmann FWH fuse Bussmann FWP fuse 500Vdc fuse errule fuse   industrial DC fuse