690VAC current limiting fuse: 100FE, 170M1322 etc;
1000VAC semiconductor fuse: 170M2682,170M3958 etc;
1000VDC PV fuse:PV-125ANH1, PV-15A10F etc;
1250VAC high speed fuse: 170M6339, 170M5138 etc;
1500VAC semiconductor fuse: 170M2083, 1500amp 1500VDC fuse; 170M6734,800amp 1500VAC fuse.
12~24KV transformer protection current limiting fuse: 12TDLEJ63, 24TDLEJ 63;
Motor ciuicuit protection fuse: 7.2CAV10;
Bussmann 12TDLEJ63 DIN Dimensioned IEC Fuse,ABPower_A bussmann fuse world.
Fuse Application:
Transformer Protection
fuse rating:
12KV,63amp;
fuse type:
DIN medium voltage fuse.
Fuse cross reference:
Cooper Xian fusegear, SDLDJ-12kV/63A.
Fuse size:
To ensure proper application of Bussmann current limiting fuse, it’s important that following additional rules be applied.
1, Current limiting fuse produce arc voltages that exceed the system voltage.
Care must be taken to make sure that the peak voltage does not exceed the insulation level of the system. If the fuse voltage rating is not permitted to exceed 140% of the system voltage, there should not be a problem. This does not mean that a higher rated fuse cannot be used, but points out that one must be assured that the system insulation level (BIL) will handle the peak arc voltage produced.
2, As with the expulsion fuse, Bussmann current-limiting fuses must be properly coordinated with other protective devices on the system. For this to happen the rules for applying an expulsion fuse must be used at all currents that cause the fuse to interrupt in 0.01 seconds or greater.
When other current-limiting protective devices are on the system it becomes necessary to use I2t values for coordination at currents causing the fuse to interrupt in less than 0.01 seconds. These values may be supplied as minimum and maximum values or minimum melting and total clearing I2t curves. In either case, the following rules should be followed.
1, The minimum melting I2t of the fuse should be greater than the total clearing I2t of the downstream current-limiting device.
2, The total clearing I2t of the fuse should be less than the minimum melting I2t of the upstream current- limiting device.
690VAC current limiting fuse: 100FE, 170M1322 etc;
1000VAC semiconductor fuse: 170M2682,170M3958 etc;
1000VDC PV fuse:PV-125ANH1, PV-15A10F etc;
1250VAC high speed fuse: 170M6339, 170M5138 etc;
1500VAC semiconductor fuse: 170M2083, 1500amp 1500VDC fuse; 170M6734,800amp 1500VAC fuse.
12~24KV transformer protection current limiting fuse: 12TDLEJ63, 24TDLEJ 63;
Motor ciuicuit protection fuse: 7.2CAV10;
Energy Storage System Electrical Protection Solution, Fuse,Pyrofuse, Breaker, Bussmann, Eaton, Litte.....
MOREBussmann fuse catalog, EV fuse,DIN type fuse, type.....
MOREEaton Bussmann 1000VDC 400A,high speed breaker...
MOREEnergy Storage System Electrical Protection Solution, Fuse,Pyrofuse, Breaker, Bussmann, Eaton, Litte.....
MOREBussmann fuse catalog, EV fuse,DIN type fuse, type.....
MOREFuses compliant with the specifications for current limiting fuses should be marked as "Current Limi.....
MORE